SL100-110KRG-W
Three Phase Grid-Connection Inverter
Efficient Income
Wide range DC voltage input, high utilization rate of power generation
Support 1.5 times over-distribution ofDC input and 1.1 times overload of AC output
Max. support for 16A string currents, with strong component adaptability
Configure PID repair and protection functions to improve system power generation
Safe and Reliable
AC/DC secondary lightning protection to make the system safer
The bus capacitor is designed with thin film + electrolytic capacitor scheme to improve the service life of the whole machine
IP66 protection, C5 anticorrosion design, adapting to harsh environment
Intelligent and Friendly
Support intelligent I-V curve scanning, one-key diagnosis and AC voltage analysis
LED display, simple and elegant
Support Bluetooth/RS485/4G/WIFI and
other communication modes
Parameter List
Model | SL100KRG-W | SL110KRG-W |
Input Data (DC) | ||
Max. Input Power | 150 kW | 165 kW |
Max. DC Voltage | 1100 V | |
Start-up Voltage | 180 V | |
Nominal Voltage | 600 V | |
MPPT Voltage Range | 200-1000 V | |
No. of MPP Trackers | 9 | |
No. of PV Strings per MPP Tracker | 2 | |
Max. Input Current per MPP Tracker | 32 A | |
Max. Input Short-circuit Current per MPPT | 40 A | |
Output Data (AC) | ||
Nominal Output Power | 100 kW | 110 kW |
Max. AC Apparent Power | 110 kVA | 121 kVA |
Nominal AC Voltage | 3L/N/PE,220 V / 380 V,230 V / 400 V | |
AC Grid Frequency | 50/60 Hz | |
Frequency Range | (45-55)/(55-65) Hz | |
Max. Output Current (PF=0.9) | 166.7 A | 175 A |
Power Factor | >0.99 (Rated) | |
Adjustable Power Factor Range | 0.8 leading…0.8 lagging | |
Max. Total Harmonic Distortion | <3% (Rated Power) | |
Efficiency | ||
Max. Efficiency | 98.5% | |
European Efficiency | 98.1% | |
MPPT Efficiency | 99.9% | |
Protection | ||
Anti-flow Protection | Optional | |
DC Reverse Polarity Protection | Yes | |
DC Switch | Yes | |
DC Surge Protection | Type II | |
Insulation Resistance Monitoring | Yes | |
Residual-current Monitoring Unit (GFCI) | Yes | |
AC Short-circuit Protection | Yes | |
AC Surge Protection | Type II | |
Grid Monitoring | Yes | |
Anti-islanding Protection | Yes | |
String Fault Monitoring | Yes | |
AFCI Protection | Optional | |
General Data | ||
Dimensions (W×H×D) | 1040 x 700 x 350 mm | |
Weight | 88 kg | |
Operating Temperature Range | –25℃~+60℃ (>45℃ derating) | |
Relative Humidity | 0~100% | |
Altitude | 4000 m (>3000 m derating) | |
Self-consumption at Night | <4 W | |
Topology | Transformerless | |
Cooling | Intelligent Air Cooling | |
Protection Rating | IP66 | |
Guarantee Period | 5 Years / 10 Years (Optional) | |
Display | LED | |
Communication | Yes:RS485/USB/Bluetooth, Optional:4G/WiFi | |
Standards Compliance | ||
Grid Connection | NB/T 32004, G98/G99, VDE 0126/4105/0124, EN 50549-1/2, CEI0-21/CEI0-16, AS 4777.2, IEC 61727/62116, PEA, MEA, RD1699/661/413/244/2019, UNE 206006/206007, NTS Type B, UNE 217002/217001 | |
Safety Standards | EN/IEC 62109-1/2 | |
Others | EN/IEC 61000-6-1/2/3/4,IEC 61683,IEC 60068(1,2,14,30) |