Hybrid Inverter SL-D10-20KTR-H40
98.4% Max. Efficiency
40A PV Input Current
10ms UPS-level Switching
110% Unbalanced Load
Parameter List
| SL-D10KTR-H40 | SL-D12KTR-H40 | SL-D15KTR-H40 | SL-D20KTR-H40 |
PV Input | ||||
---|---|---|---|---|
Max. Input power (kW) | 15 | 18 | 22.5 | 30 |
Max. DC input Voltage* (V) | 1000* | |||
MPPT voltage range* (V) | 200~950* | |||
Start-up voltage (V) | 135 | |||
Rated input voltage (V) | 620 | |||
Max. input current per MPPT (A) | 30/30 | |||
Max. short-circuit current (A) | 40/40 | |||
Number of MPP trackers | 2 | |||
Max. number of inputs | 2/2 | |||
Battery Side | ||||
Battery Type | Lithium Battery (with BMS) | |||
Battery Voltage Range (V) | 135~750 | |||
Max. Charging/Discharging Current (A) | 40/40 | |||
Grid Side | ||||
Rated output power (kW) | 10 | 12 | 15 | 20 |
Max. Output Apparent Power(kVA) | 11.01) | 13.2 | 16.53) | 22 |
Max. Input Apparent Power ** (kVA) | 20 | 24 | 30 | 30 |
Max. Charging Power of battery(kW) | 10 | 12 | 15 | 20 |
Rated output voltage (V) | 3L/N/PE; 220/380; 230/400; 240/415 | |||
Rated AC grid frequency (Hz) | 50/60 | |||
Max. output current (A) | 16.52) | 20 | 25.04) | 33.5 |
Adjustable power factor | 0.8 leading …0.8 lagging | |||
Max. total harmonic distortion | <3% @Rated output power | |||
DCI | <0.5%In | |||
Back-up Side | ||||
Rated output power (kW) | 10 | 12 | 15 | 20 |
Max. Output Apparent Power(kVA) | 11 | 13.2 | 16.5 | 22 |
Max. output current (A) | 16.5 | 20 | 25 | 33.5 |
UPS switching time (ms) | <10 | <10 | <10 | <10 |
Rated output voltage (V) | 3L/N/PE; 220/380; 230/400; 240/415 | |||
Rated output frequency (Hz) | 50/60 | 50/60 | 50/60 | 50/60 |
Voltage harmonic distortion | <3% @Linear load | |||
Efficiency | ||||
Max. efficiency | 98.40% | |||
European Efficiency | 97.50% | |||
Compliance | IEC/EN 62109, IEC/EN 61000, EN50549-1, TOR Generator Type A, VDE-AR-N-4105 |
* PV Max. Input voltage is 950V without battery, or 850V with battery, otherwise inverter will be waiting;
** Max apparent power from the grid means the maximum power imported from the utility grid used to satisfy the backup loads and charge the battery;
1) G98: 10.5kVA; 2) G98: 16.00A; 3) AS 4777.2: 15.0kVA; 4) AS 4777.2: 21.7A
Protection | |
DC Reverse Polarity Protection | Integrated |
Battery Input Reverse Connection-Protection | Integrated |
Insulation Resistance Protection | Integrated |
Surge Protection | Integrated |
Over-temperature Protection | Integrated |
Residual Current Protection | Integrated |
Islanding Protection | Integrated |
AC Over-voltage Protection | Integrated |
Overload Protection | Integrated |
AC Short-circuit Protection | Integrated |
General Data | |
Over Voltage Category | PV: Ⅱ;Main: Ⅲ |
Dimensions (W×H×D mm) | 534×418×210 |
Weight (kg) | 28.0 (10~12kW)/31.0 (15~20kW) |
Protection Degree | IP65 |
Standby Self-consumption (W) | <15 |
Topology | Transformerless |
Operating Temperature Range (°C) | -30~60 |
Relative Humidity (%) | 0~100 |
Operating Altitude (m) | 3000 (>3000m derating) |
Cooling | Natural Convection |
Noise Level (dB) | <40 |
Display | OLED & LED |
Communication | CAN, RS485, WiFi/LAN (Optional) |