Hybrid Inverter SL3-8KLH-W
Parameter List
Model | SL3KLH-W | SL3.6KLH-W | SL4.2KLH-W | SL5KLH-W | SL6KLH-W | SL8KLH-W |
PV (DC) | ||||||
---|---|---|---|---|---|---|
Max. PV Input Power* | 7000 Wp | 7000 Wp | 12600 Wp | 13000 Wp | 14000 Wp | 16000 Wp |
Max. Input Voltage** | 600 V | |||||
Start-up Voltage | 120 V | |||||
Rated Input Voltage | 370 V | |||||
MPPT Input Voltage Range** | 100-550 V | |||||
MPPT Max. Input Current | 16 A | 16 A / 16 A | 16 A / 32 A | |||
MPPT Short-circuit Current | 20 A | 20 A / 20 A | 20 A / 40 A | |||
No. of MPPT | 1 | 2 | ||||
No. of Strings per MPPT | 1 | 1 / 1 | 1 / 2 | |||
Grid (AC) | ||||||
Max. Input Apparent Power*** | 10350 VA | 16000 Wp | ||||
Rated Output Power | 3000 W | 3680 W | 4600 W | 5000 W | 6000 W | 8000 W |
Max. Output Apparent Power | 3000 VA | 3680 VA | 4600 VA | 5000 VA | 6000 VA | 8000 VA |
Rated AC Voltage | L/N/PE, 220/230/240 V | |||||
Input/Output Voltage Range | 154-276 V | |||||
Rated Output Voltage Frequency | 50/60 Hz | |||||
Input/Output Voltage Frequency Range | (45-55)/(55-65) Hz | |||||
Rated Output Current | 13.04 A | 16.00 A | 20.00 A | 21.74 A | 26.09 A | 34.78 A |
Max. Input/Output Current*** | 45 / 16 A | 45 / 18 A | 45 / 23 A | 45 / 25 A | 45 / 28 A | 55 / 36 A |
Power Factor (Rated) | >0.99 | |||||
Adjustable Power Factor Range | 0.8 leading ... 0.8 lagging | |||||
Total Harmonic Distortion | <3% (Rated Power) | |||||
Max. PV Input Power* | L/N/PE | |||||
AC Load Output (Off-grid) | ||||||
Rated Output Power | 3000 W | 3680 W | 4600 W | 5000 W | 6000 W | 8000 W |
Max. Output Apparent Power | 10000 VA@600s | |||||
Rated Output Voltage | L/N/PE, 220/230/240 V | |||||
Output Voltage Range | 154-276 V | |||||
Rated Output Frequency | 50/60 Hz | |||||
Rated Output Current | 13.04 A | 16.00 A | 20.00 A | 21.74 A | 26.09 A | 34.78 A |
Max. Output Current | 45 A | |||||
Total Harmonic Distortion | <3% (R Load) | |||||
On-grid/Off-grid Switching Time | <10 ms | |||||
Battery (DC) | ||||||
Max.Charge/Discharge Power | 8000 W / 8000 W | |||||
Battery Voltage Range | 85-460 VDC | |||||
Max. Charge/Discharge Current | 32A / 32 A | |||||
Communication Port | CAN/RS485 | |||||
Efficiency | ||||||
Max. efficiency | 97.6% | |||||
Max. MPPT Efficiency | 99.9% | |||||
Max. European Efficiency | 97.0% |
*Recommanded PV power should be considered by battery capcity and actual household load.
**Max. PV input voltage is 460V when battery input voltage is less than 150V.
***The max. input power & current from grid refers to the ability of the inverter to charge the battery and bearing the load at the same time.
Protection | |
Integrated Protection | Anti-flow Protection, DC Reverse Protection, DC Circuit Breaker, Monitoring, Output Shorted Protection, Output Over Current Protection, Residual Current Monitoring, BAT reverse Polarity Protection, BAT Shorted Protection, |
Surge Protection | DC Type II, AC Type II |
Display and Communication | |
---|---|
Display | LED+APP |
Communication | RS485 / WiFi, 4G (Optional) |
General ` | |
Dimensions (W×H×D) | 516×442×222 mm |
Weight | 22.5 kg |
Operating Temperature Range | -30~60 ℃ |
Noise | <30 dB |
Cooling | Natural Convection |
Installation Style | Wall-mounted |
Protection Rating | IP66 |
Warranty | 10 Years |
Standards Compliance | |
---|---|
Grid Connection | CEI 0-21, UNE 217001, UNE 217002, NTS Type A, VDE 4105, VDE 0126, EN 50438, G98, G99, EN50549, AS 4777.2 |
Safety Regulation | EN/IEC 62109-1/2 |
Others | EN/IEC 61000-6-1/3 |