Hybrid Inverter SL3-8KLH-W

Parameter List

Model

SL3KLH-W

SL3.6KLH-W

SL4.2KLH-W

SL5KLH-W

SL6KLH-W

SL8KLH-W

PV (DC)

Max. PV Input Power*

7000 Wp

7000 Wp

12600 Wp

13000 Wp

14000 Wp

16000 Wp

Max. Input Voltage**

600 V

Start-up Voltage

120 V

Rated Input Voltage

370 V

MPPT Input Voltage Range**

100-550 V

MPPT Max. Input Current

16 A

16 A / 16 A

16 A / 32 A

MPPT Short-circuit Current

20 A

20 A / 20 A

20 A / 40 A

No. of MPPT

1

2

No. of Strings per MPPT

1

1 / 1

1 / 2

Grid (AC)

Max. Input Apparent Power***

10350 VA

16000 Wp

Rated Output Power

3000 W

3680 W

4600 W

5000 W

6000 W

8000 W

Max. Output Apparent Power

3000 VA

3680 VA

4600 VA

5000 VA

6000 VA

8000 VA

Rated AC Voltage

L/N/PE, 220/230/240 V

Input/Output Voltage Range

154-276 V

Rated Output Voltage Frequency

50/60 Hz

Input/Output Voltage Frequency Range

(45-55)/(55-65) Hz

Rated Output Current

13.04 A

16.00 A20.00 A21.74 A26.09 A34.78 A

Max. Input/Output Current***

45 / 16 A

45 / 18 A

45 / 23 A

45 / 25 A

45 / 28 A

55 / 36 A

Power Factor (Rated)

>0.99

Adjustable Power Factor Range

0.8 leading ... 0.8 lagging

Total Harmonic Distortion

<3% (Rated Power)

Max. PV Input Power*

L/N/PE

AC Load Output (Off-grid)

Rated Output Power

3000 W

3680 W

4600 W

5000 W

6000 W

8000 W

Max. Output Apparent Power

10000 VA@600s

Rated Output Voltage

L/N/PE, 220/230/240 V

Output Voltage Range

154-276 V

Rated Output Frequency

50/60 Hz

Rated Output Current

13.04 A

16.00 A

20.00 A

21.74 A

26.09 A

34.78 A

Max. Output Current

45 A

Total Harmonic Distortion

<3% (R Load)

On-grid/Off-grid Switching Time

<10 ms

Battery (DC)

Max.Charge/Discharge Power

8000 W / 8000 W

Battery Voltage Range

85-460 VDC

Max. Charge/Discharge Current

32A / 32 A

Communication Port

CAN/RS485

Efficiency

Max. efficiency

97.6%

Max. MPPT Efficiency

99.9%

Max. European Efficiency

97.0%

*Recommanded PV power should be considered by battery capcity and actual household load.
**Max. PV input voltage is 460V when battery input voltage is less than 150V.
***The max. input power & current from grid refers to the ability of the inverter to charge the battery and bearing the load at the same time.

Protection

Integrated Protection

Anti-flow Protection, DC Reverse Protection, DC Circuit Breaker,
Insulation Resistor Detection, GFCI Leakage Current

Monitoring, Output Shorted Protection, Output Over Current Protection,
Grid Monitoring, Anti-islanding Protection,

Residual Current Monitoring, BAT reverse Polarity Protection, BAT Shorted Protection,
Off-grid Overload Protection

Surge Protection

DC Type II, AC Type II

Display and Communication

Display

LED+APP

Communication

RS485 / WiFi, 4G (Optional)

General `

Dimensions (W×H×D)

516×442×222 mm

Weight

22.5 kg

Operating Temperature Range

-30~60 ℃

Noise

<30 dB

Cooling

Natural Convection

Installation Style

Wall-mounted

Protection Rating

IP66

Warranty

10 Years

Standards Compliance

Grid Connection

CEI 0-21, UNE 217001, UNE 217002, NTS Type A, VDE 4105, VDE 0126, EN 50438, G98, G99, EN50549, AS 4777.2

Safety Regulation

EN/IEC 62109-1/2

Others

EN/IEC 61000-6-1/3

Copyright © 2023 Slenergy Technology (A.H.) Co., Ltd.