SL100-136KRG-W

Three Phase Grid-Connection Inverter

  • Efficient Income

  • Wide range DC voltage input, high utilization rate of power generation

  • Support 1.5 times over-distribution ofDC input and 1.1 times overload of AC output

  • Max. support for 16A string currents, with strong component adaptability

  • Configure PID repair and protection functions to improve system power generation

  • Safe and Reliable

  • AC/DC secondary lightning protection to make the system safer

  • The bus capacitor is designed with thin film + electrolytic capacitor scheme to improve the service life of the whole machine

  • IP66 protection, C5 anticorrosion design, adapting to harsh environment

  • Intelligent and Friendly

  • Support intelligent I-V curve scanning, one-key diagnosis and AC voltage analysis

  • LED display, simple and elegant

  • Support Bluetooth/RS485/4G/WIFI and

  • other communication modes

Parameter List

Technical Data

SL100KRG-W

SL110KRG-W

SL120KRG-W

Input Data (DC)

Max. Input Power (for Module STC)

150 kW

165 kW

180 kW 

Max. DC Voltage

1100 V

Start-up Voltage

200 V

Nominal Voltage

600 V

720 V

MPPT Voltage Range

180~1000 V

No. of MPP Trackers

9

9
12

No. of PV Strings per MPP Tracker

2 / 2 / 2

Max. Input Current per MPP Tracker

32A*3

Max. Input short Current per MPP Tracker

40A*3

Output Data (AC)

Nominal Output Power

100 kW

110 kW

120 kW

Max. AC Apparent Power

110 kVA

121 kVA

132 kVA

Nominal AC Voltage

230 V / 400 V

AC Grid Frequency (Range)

50 / 60 Hz (45~55 Hz / 55~65 Hz)

Max. Output Current (PF=0.9)

166.7 A

175.4 A

158.7 A

Adjustable Power Factor

0.8leading…0.8lagging

THDi

<3%

AC Grid Connection Type

3L/N/PE or 3L/PE

Efficiency

Max. Efficiency

98.5%

European Efficiency

98.1%

MPPT Efficiency

99.9%

Protection

DC Reverse Polarity Protection

Yes

DC Switch

Yes

AC/DC Surge Protection

Type III (Type II Optional)

Insulation Resistance Monitoring

Yes

AC Short-circuit Protection

Yes

Grid Monitoring

Yes

Anti-islanding Protection

Yes

Residual-current Monitoring Unit

Yes

String Fault Monitoring

Optional

AFCI Protection

Optional

General Data

Dimensions (W×H×D)

1022 x 670 x 346 mm

Weight

≤90 kg

Operating Temperature Range

–30°C ~ +60°C (>45°C derating)

Relative Humidity

0~100%

Altitude

5000 m (>4000 m derating)

Self-consumption at Night

< 3 W

Topology

Transformerless

Cooling

Intelligent Air Cooling

Protection Degree

IP66

Guarantee Period

5 Years /10 Years(Optional)

Display and Communication

Display

LED

Communication

Yes:RS485,Optional:4G/WiFi/Bluetooth

Criteria Met

Grid Connection Standards

G98/G99, VDE0126, VDE4105, VDE0124, EN50438, EN50549-1/2, CEI0-21/CEI 0-16, AS4777.2, IEC61727, IEC62116, PEA, MEA

Safety Standards

IEC62109-1/2, IEC62116, IEC61727, IEC61683, IEC60068(1,2,14,30)

EMC Standards

EN61000-6-1/2/3/4